Fantech Trade STYLVENT-150/230/300 Wall Mounted Fan - IPX4
Overview
Stylvent wall and window fans
Weather- and impact-resistant fans for residential or commercial ventilation, with model-specific exhaust and supply options.
Features
Weather-resistant housing
The housing is designed for wall or window mounting.
Continuous duty
The range is rated for continuous running.
Removable cover
The front cover removes for cleaning.
Model-specific airflow direction
HV150 is exhaust only; HV230 and HV300 can also supply air.
Specifications
- Supply frequency
- 50 Hz
- IP rating
- IPX4
Options
HV-150AE
- Ozlighting SKU
- FT-HV-150AE
- Manufacturer code
- HV-150AE
- Dimension A (supplier diagram)
- 230 mm
- Dimension B (supplier diagram)
- 251 mm
- Dimension C (supplier diagram)
- 110 mm
- Dimension DØ Min. (supplier diagram)
- 185 mm
- Dimension DØ Max. (supplier diagram)
- 190 mm
- Dimension E (supplier diagram)
- 130 mm
- Dimension F (supplier diagram)
- 306 mm
- Airflow (m³/h)
- 225 m³/h
- Airflow (L/s)
- 63 L/s
- Fan speed
- 1800 rpm
- Sound pressure at 3 m
- 39 dB(A)
- Motor power
- 32 W
- Supply voltage
- 220-240 V AC
- IP Rating
- IPX4
- Mounting hole diameter
- 185–190 mm
- Airflow mode
- Exhaust only
HV-230AE
- Ozlighting SKU
- FT-HV-230AE
- Manufacturer code
- HV-230AE
- Dimension A (supplier diagram)
- 300 mm
- Dimension B (supplier diagram)
- 325 mm
- Dimension C (supplier diagram)
- 142 mm
- Dimension DØ Min. (supplier diagram)
- 259 mm
- Dimension DØ Max. (supplier diagram)
- 262 mm
- Dimension E (supplier diagram)
- 182 mm
- Dimension F (supplier diagram)
- 440 mm
- Airflow (m³/h)
- 600 m³/h
- Fan speed
- 1250 rpm
- Sound pressure at 3 m
- 43 dB(A)
- Motor power
- 34 W
- Supply voltage
- 230-240 V AC
- IP Rating
- IPX4
- Mounting hole diameter
- 259–262 mm
- Airflow mode
- Exhaust or supply; SRS needed for reversible operation
HV-300AE
- Ozlighting SKU
- FT-HV-300AE
- Manufacturer code
- HV-300AE
- Dimension A (supplier diagram)
- 368 mm
- Dimension B (supplier diagram)
- 403 mm
- Dimension C (supplier diagram)
- 150 mm
- Dimension DØ Min. (supplier diagram)
- 327 mm
- Dimension DØ Max. (supplier diagram)
- 330 mm
- Dimension E (supplier diagram)
- 215 mm
- Dimension F (supplier diagram)
- 570 mm
- Airflow (m³/h)
- 1100 m³/h
- Airflow (L/s)
- 306 L/s
- Fan speed
- 1150 rpm
- Sound pressure at 3 m
- 46 dB(A)
- Motor power
- 68 W
- Supply voltage
- 230-240 V AC
- IP Rating
- IPX4
- Mounting hole diameter
- 327–330 mm
- Airflow mode
- Exhaust or supply; SRS needed for reversible operation
Dimensions labelled A, B or other letters refer to the manufacturer’s model-specific drawing. Airflow and sound ratings refer to the stated test conditions; installed performance depends on the ventilation system.
Inclusions
Selected Stylvent fan. Reversing switch, wall rods and weather caps are sold separately.
Installation requirements
Electrical installation and any fixed wiring must be completed by a qualified electrician. Follow the manufacturer’s installation instructions and provide access for maintenance. HV150AE is exhaust only. Reversible operation on HV230AE or HV300AE requires the separate SRS reversing switch. For suitable 25–300 mm walls, WALLRODSPK is required separately. Optional weather caps are separate.