Fantech Trade HEAT TRANSFER MOUNTED FAN - KIT IP44
Overview
Heat-transfer fan kits
Matched fan, insulated duct and adjustable grille kits that move warm air from a heated room to one, two or three rooms.
Features
Room-specific kit
Select the one-, two- or three-room layout.
Insulated duct included
The supplied duct length varies by kit.
Adjustable grilles
The kit includes the matched internal grille set.
Optional thermostat
TFC6 temperature control is available separately.
Specifications
- Application
- Warm-air transfer between rooms
Options
- Control thermostat
- TFC6 optional, not supplied
FTPHTK1-1
- Ozlighting SKU
- FT-FTPHTK1-1
- Manufacturer code
- FTPHTK1-1
- Rooms
- 1
- Fan power
- 28 W
- Installed-kit airflow
- 62 L/s
- Fan-only airflow
- 86 L/s
- Sound pressure at 3 m
- 45 dB(A)
- Insulated duct supplied
- 9 m
- Maximum intake-to-outlet run
- 9 m
- Kit contents
- 150 mm axial fan; 9 m insulated duct; 2 × 150 mm grilles; duct tape
FTPHTK1-2
- Ozlighting SKU
- FT-FTPHTK1-2
- Manufacturer code
- FTPHTK1-2
- Rooms
- 2
- Fan power
- 50 W
- Installed-kit airflow
- 107 L/s
- Fan-only airflow
- 160 L/s
- Sound pressure at 3 m
- 45 dB(A)
- Insulated duct supplied
- 12 m
- Maximum intake-to-outlet run
- 9 m
- Kit contents
- 150 mm mixed-flow fan; 12 m insulated duct; 3 × 150 mm grilles; 150 mm branch; duct tape
FTPHTK1-3
- Ozlighting SKU
- FT-FTPHTK1-3
- Manufacturer code
- FTPHTK1-3
- Rooms
- 3
- Fan power
- 120 W
- Installed-kit airflow
- 183 L/s
- Fan-only airflow
- 280 L/s
- Sound pressure at 3 m
- 51 dB(A)
- Insulated duct supplied
- 15 m
- Maximum intake-to-outlet run
- 12 m
- Kit contents
- 200 mm mixed-flow fan; 15 m insulated duct; 3 × 150 mm and 1 × 200 mm grilles; 200 mm branch; duct tape
Airflow and sound ratings refer to the stated test conditions; installed performance depends on the ventilation system.
Inclusions
Fan, insulated duct, grilles and fittings listed for the selected kit in Options. Heat source, thermostat and speed controller are not included.
Installation requirements
Electrical installation and any fixed wiring must be completed by a qualified electrician. Follow the manufacturer’s installation instructions and provide access for maintenance. A heat source and any thermostat or speed controller are separate. Maximum distance from intake to each outlet is 9 m for the one- and two-room kits and 12 m for the three-room kit. The supplier’s example rooms are 4 × 4 × 2.5 m; larger rooms may need additional outlets.
Documentation