{"product_id":"eglo-delay-off-timer-for-exhaust-fans","title":"Eglo Delay Off Timer - for Exhaust Fans","description":"\u003cdiv class=\"oz-eglo\"\u003e\n\u003cstyle\u003e\n.oz-eglo.oz-eglo{padding:24px!important;padding-left:clamp(16px,3vw,24px)!important;background:#fff;color:#173e43;font-family:Arial,sans-serif;font-size:16px;line-height:1.6;width:100%!important;max-width:100%!important;overflow-wrap:anywhere}\n.oz-eglo.oz-eglo,.oz-eglo.oz-eglo *{box-sizing:border-box!important}\n.oz-eglo.oz-eglo h2,.oz-eglo.oz-eglo h3,.oz-eglo.oz-eglo p,.oz-eglo.oz-eglo dl,.oz-eglo.oz-eglo dt,.oz-eglo.oz-eglo dd{margin:0!important;line-height:1.5!important}\n.oz-eglo.oz-eglo h2{font-size:clamp(24px,3vw,34px)!important;font-weight:700!important;color:#173e43!important}\n.oz-eglo.oz-eglo h3{font-size:20px!important;font-weight:700!important;color:#173e43!important;margin-bottom:14px!important}\n.oz-eglo.oz-eglo section{margin:0 0 28px!important;padding:0!important;min-width:0!important}\n.oz-eglo.oz-eglo .hero{border-top:4px solid #1ca1a9;padding:24px!important;background:#f5f7f6}\n.oz-eglo.oz-eglo .logo{display:block!important;width:180px!important;max-width:100%!important;height:auto!important;margin:0 0 22px!important}\n.oz-eglo.oz-eglo .intro{margin-top:12px!important;max-width:65ch}\n.oz-eglo.oz-eglo .warning{padding:20px!important;border-left:4px solid #1ca1a9;background:#edf6f6}\n.oz-eglo.oz-eglo .grid{display:grid!important;grid-template-columns:repeat(4,minmax(0,1fr))!important;gap:14px!important;grid-auto-rows:1fr!important;align-items:stretch!important;justify-items:stretch!important;width:100%!important;margin:0!important;padding:0!important}\n.oz-eglo.oz-eglo .card{display:flex!important;flex-direction:column!important;align-self:stretch!important;width:100%!important;min-width:0!important;height:100%!important;padding:18px!important;margin:0!important;position:relative!important;top:auto!important;bottom:auto!important;left:auto!important;right:auto!important;transform:none!important;border:1px solid #cbdcdd;background:#fff;transition:border-color 200ms ease}\n.oz-eglo.oz-eglo .card:hover{border-color:#1ca1a9}\n.oz-eglo.oz-eglo .card strong{font-size:22px;color:#173e43;line-height:1.4;margin-bottom:5px}\n.oz-eglo.oz-eglo dl{display:grid!important;grid-template-columns:minmax(140px,1fr) minmax(0,2fr)!important;width:100%!important;padding:0!important}\n.oz-eglo.oz-eglo dt,.oz-eglo.oz-eglo dd{padding:12px 16px!important;border-bottom:1px solid #dde5e5;min-width:0!important}\n.oz-eglo.oz-eglo dt{font-weight:700;background:#f5f7f6}\n.oz-eglo.oz-eglo ul{margin:0!important;padding:0 0 0 22px!important;list-style:disc!important}\n.oz-eglo.oz-eglo a{color:#126b72!important;text-decoration:underline!important}\n.oz-eglo.oz-eglo a:focus-visible{outline:2px solid #173e43;outline-offset:3px}\n@media(max-width:900px){.oz-eglo.oz-eglo .grid{grid-template-columns:repeat(2,minmax(0,1fr))!important}}\n@media(max-width:540px){.oz-eglo.oz-eglo{padding:16px!important}.oz-eglo.oz-eglo .grid{grid-template-columns:1fr!important;grid-auto-rows:auto!important}.oz-eglo.oz-eglo dl{grid-template-columns:1fr!important}.oz-eglo.oz-eglo dd{padding-top:6px!important}.oz-eglo.oz-eglo dt{border-bottom:0}}\n@media(prefers-reduced-motion:reduce){.oz-eglo.oz-eglo *,.oz-eglo.oz-eglo *::before,.oz-eglo.oz-eglo *::after{animation:none!important;transition:none!important;scroll-behavior:auto!important}}\n.oz-eglo.oz-eglo,.oz-eglo.oz-eglo::before,.oz-eglo.oz-eglo::after,.oz-eglo.oz-eglo *,.oz-eglo.oz-eglo *::before,.oz-eglo.oz-eglo *::after{border-radius:2px!important}\n\u003c\/style\u003e\n\u003csection class=\"hero\"\u003e\u003cimg class=\"logo\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0237\/5801\/2480\/files\/brands-eglo_1628058076__31197.original.jpg?v=1728955923\" alt=\"EGLO\" width=\"180\" height=\"49\"\u003e\u003ch2\u003eDelay Off Timer for Exhaust Fans\u003c\/h2\u003e\n\u003cp class=\"intro\"\u003eKeep a connected exhaust fan or motor load running after the wall switch is turned off. Choose one of 16 delay settings, from 30 seconds to 120 minutes, using the module DIP switches.\u003c\/p\u003e\u003c\/section\u003e\u003csection class=\"warning\"\u003e\u003ch3\u003eImportant before you buy\u003c\/h3\u003e\n\u003cp\u003eInstallation must be carried out by a licensed electrician. The connected load must be between 4W and 250W, with a 220-240V AC, 50\/60Hz supply. Isolate power before wiring or adjusting the module.\u003c\/p\u003e\u003c\/section\u003e\u003csection aria-label=\"Key highlights\"\u003e\u003cdiv class=\"grid\"\u003e\n\u003cdiv class=\"card\"\u003e\n\u003cstrong\u003e16 settings\u003c\/strong\u003e\u003cspan\u003e30 seconds to 120 minutes\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card\"\u003e\n\u003cstrong\u003e4-250W\u003c\/strong\u003e\u003cspan\u003eWorking load\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card\"\u003e\n\u003cstrong\u003e220-240V AC\u003c\/strong\u003e\u003cspan\u003e50\/60Hz supply\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card\"\u003e\n\u003cstrong\u003e65 x 26 x 18mm\u003c\/strong\u003e\u003cspan\u003eModule dimensions\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection\u003e\u003ch3\u003eOperation and compatibility\u003c\/h3\u003e\n\u003cp\u003eAvailable delay settings are 30 seconds, 2, 5, 10, 15, 20, 30, 40, 50, 60, 70, 80, 90, 100, 110 and 120 minutes. Switching on applies power to the load; switching off starts the countdown. Use the exact DIP-switch pattern in the instructions.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003cdl\u003e\n\u003cdt\u003eSupply voltage\u003c\/dt\u003e\n\u003cdd\u003e220-240V AC, 50\/60Hz\u003c\/dd\u003e\n\u003cdt\u003eWorking load\u003c\/dt\u003e\n\u003cdd\u003e4W minimum to 250W maximum\u003c\/dd\u003e\n\u003cdt\u003eDelay range\u003c\/dt\u003e\n\u003cdd\u003e30 seconds to 120 minutes\u003c\/dd\u003e\n\u003cdt\u003eTiming settings\u003c\/dt\u003e\n\u003cdd\u003e16 DIP-switch settings\u003c\/dd\u003e\n\u003cdt\u003eAmbient operating temperature\u003c\/dt\u003e\n\u003cdd\u003e0-40 degrees Celsius\u003c\/dd\u003e\n\u003cdt\u003eBody material\u003c\/dt\u003e\n\u003cdd\u003eABS\u003c\/dd\u003e\n\u003c\/dl\u003e\u003c\/section\u003e\u003csection\u003e\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdl\u003e\n\u003cdt\u003eLength\u003c\/dt\u003e\n\u003cdd\u003e65mm\u003c\/dd\u003e\n\u003cdt\u003eWidth\u003c\/dt\u003e\n\u003cdd\u003e26mm\u003c\/dd\u003e\n\u003cdt\u003eHeight\u003c\/dt\u003e\n\u003cdd\u003e18mm\u003c\/dd\u003e\n\u003cdt\u003eNet weight\u003c\/dt\u003e\n\u003cdd\u003e0.03kg\u003c\/dd\u003e\n\u003c\/dl\u003e\u003c\/section\u003e\u003csection\u003e\u003ch3\u003eWhat's included\u003c\/h3\u003e\n\u003cp\u003eDelay-off timer module. Exhaust fan or motor load sold separately.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003ch3\u003eInstallation and care\u003c\/h3\u003e\n\u003cp\u003eFollow the wiring diagram and DIP-switch table in the official instructions. Operate within the specified 0-40 degrees Celsius ambient temperature range.\u003c\/p\u003e\u003c\/section\u003e\u003csection\u003e\u003ch3\u003eOfficial documents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/tools.eglo.com\/tds\/eng-GB\/207933\" target=\"_blank\" rel=\"noopener\"\u003e207933: official datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.eglo.com\/media\/catalog\/product\/dam\/BDA\/207933_BDA.pdf\" target=\"_blank\" rel=\"noopener\"\u003e207933: installation instructions\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Eglo","offers":[{"title":"Default Title","offer_id":53068440535352,"sku":"EGL-207933","price":39.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0237\/5801\/2480\/files\/Eglo-Delay-Off-Timer-for-Exhaust-Fans-Eglo.jpg?v=1790909472","url":"https:\/\/www.ozlighting.com.au\/products\/eglo-delay-off-timer-for-exhaust-fans","provider":"Ozlighting","version":"1.0","type":"link"}